Icon Jeremias Industrielle Anwendungen
  1. Products
  2. References

References steel chimneys

Every steel chimney is unique because each one is designed and manufactured for a specific project.

With decades of experience and expertise in industrial chimneys, we proudly refer to over 4,000 completed industrial projects! Here, you will find a wide selection of steel chimneys that we have produced and installed. Discover a large number of reference projects successfully carried out by Jeremias – see for yourself!

Select your desired reference by country, plant type, or product series!

country
System type
Series
CountryGermany
System typeexhaust
Series FSA
ProductFSA
Flues1
Height10 m
Ø support pipe914 mm
Ø inner pipe604 mm
CountryGermany
System typeCHP
Series FSA-X
ProductFSA-2
Flues2
Height20 m
Ø support pipe813 mm
Ø inner pipeeach 219 mm
CountryGermany
System typeCHP
Series FSA-X
ProductFSA-3
Flues3
Height12 m
Ø support pipe711 mm
Ø inner pipeeach 154 mm
CountryGermany
System typeBoiler
Series FSA
Product2x FSA
Flues2
Height18 m
Ø support pipe1450 mm
Ø inner pipe1204 mm
CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height39 m
Ø support pipe1016 mm
Ø inner pipe734 mm
CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height24,2 m
Ø support pipe1016 mm
Ø inner pipe804 mm
CountryGermany
System typeexhaust
Series FSC
ProductFSC-steel
Flues1
Height31,47 m
Ø support pipe2000 mm
CountryGermany
System typeexhaust
Series FSA
ProductFSA
Flues1
Height22,2 m
Ø support pipe2050 mm
Ø inner pipe1804 mm
CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height19,65 m
Ø support pipe1016 mm
​​​​​​​Ø inner pipe804 mm
CountrySwitzerland
System typeBoiler
Series FSA
Product2x FSA
Flues2
Height22 m
Ø support pipe762 mm
Ø inner pipe554 mm
CountryGermany
System typeCHP, Boiler, exhaust
Series FSA-X
ProductFSA-4
Flues4
Height20,4 m
Ø support pipe1500 mm
Ø inner pipe1x 355 mm; 1x 902 mm; 1x 254 mm; 1x 139,7 mm
CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height14 m
Ø support pipe559 mm
Ø inner pipe254 mm
CountryGermany
System typeexhaust
Series FSA
ProductFSA
Flues1
Height16,75 m
Ø support pipe610 mm
Ø inner pipe354 mm
CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height16,865 m
Ø support pipe508 mm
Ø inner pipe204 mm
CountryGermany
System typeGenerators / emergency power generators
Series FSA
ProductFSA
Flues1
Height24,7 m
Ø support pipe711 mm
Ø inner pipe404 mm
CountryGermany
System typeGenerators / emergency power generators
Series FSB
Product6x FSB
Flues6
Height26,086 m
Ø support pipe604 mm
CountryGermany
System typeCHP
Series FSA-X
ProductFSA-3
Flues3
Height13,7 m
Ø support pipe1220 mm
Ø inner pipe3x 354 mm
CountryGermany
System typeGenerators / emergency power generators
Series FSA-X
ProductFSA-3
Flues3
Height18 m
Ø support pipe1500 mm
Ø inner pipe3x 404 mm
CountrySwitzerland
System typeGenerators / emergency power generators
Series FSA
Product6x FSA
Flues6
Height22,52 m
Ø support pipe813 mm
Ø inner pipe554 mm
CountrySwitzerland
System typeGenerators / emergency power generators
Series FSA
Product5x FSA
Flues5
Heightje 23,82 m
Ø support pipeje 813 mm
Ø inner pipeje 504 mm

Erweiterung: Im ersten Projekt wurden bereits 10 FSA installiert. Nun, einige Zeit später folgten weitere 5 FSA in beinah identischer Bauweise.

CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height20,35 m
Ø support pipe813 mm
Ø inner pipe404 mm
CountryGermany
System typeGenerators / emergency power generators
Series FSA
ProductFSA
Flues1
Height12,1 m
Ø support pipe1016 mm
Ø inner pipe604 mm
CountryGermany
System typeVentilation
SeriesFSC
ProductFSC-steel
Flues1
Height30 m
Ø support pipe2300 mm
CountryGermany
System typeVentilation
Series FSC
ProductFSC-steel
Flues1
Height15 m
Ø support pipe1016 mm
CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height13,5 m
Ø support pipe660 mm
Ø inner pipe454 mm
CountryGermany
System typeRoasting machine
Series FSA
ProductFSA
Flues1
Height27,5 m
Ø support pipe1016 mm
Ø inner pipe714 mm
CountryGermany
System typeVentilation
Series FSC
ProductFSC-steel
Flues1
Height23 m
Ø support pipe1420 mm
CountryGermany
System typeCHP
Series FSA-X
ProductFSA-6, Connecting pipes, 2 Anchor baskets
Flues6
Height25 m
Ø support pipe1650 mm
Ø inner pipeeach 354 mm
CountryGermany
System typeGenerators / emergency power generators
Series FSA-X
Product4 FSA-2
Flues8
Height28,4 m
Ø support pipe1x 1420 mm, 2x 1600 mm
Ø inner pipe2x 404 mm, 4x 504 mm
CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height17,7 m
Ø support pipe660 mm
Ø inner pipe404 mm
CountryGermany
System typeVentilation
Series FSC
ProductFSC-steel
Flues1
Height27 m
Ø support pipe2000 mm
CountryGermany
System typeBoiler
Series FSA
Product3x FSA
Flues1
Height2x 35,998 m, 1x 33,5005 m
Ø support pipe2x 1700 mm, 1x 1850 mm
Ø inner pipe2x 1505 mm, 1x 1650 mm
CountryGermany
System typeBoiler
SeriesFSA-X, silencer
Product2 FSA-2,  Baffle silencer
Flues2
Height23,5 m
Ø support pipe1750 mm; 1220 mm
Ø inner pipe704 mm; 454 mm

Both FSA with stainless steel cladding

CountryGermany
System typeCHP
SeriesFSA-X
ProductFSA-5, 5 VBL
Flues5
Height33,5 m 
Ø support pipe2700 mm
Ø inner pipeeach 804 mm
CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height18 m 
Ø support pipe804 mm
CountryItaly
System typeRoasting machine
Series FS-RM
ProductFS-RM
Flues2
Height6,2 m 
Ø support pipeeach 406 mm
CountryGermany
System typeVentilation
Series FSA-RM
Product3x FSA-RM, baffle silencer
Flues3
Heighteach 41,3 m 
Ø support pipeeach 1800 mm
Ø inner pipeeach 1606 mm

 

 

CountryNetherlands
System typeRoasting machine
Series FSA-X
ProductFSA-3
Flues3
Height30 m 
Ø support pipe2700 mm
Ø inner pipe2x 1128 mm, 1x 904 mm
CountryGermany
System typeBoiler
Series FSA-X
ProductFSA-2
Flues2
Height32 m
Ø support pipe3150 mm
Ø inner pipe1404 mm
CountryAustria
System typeBoiler
Series FSA, silencer
ProductFSA, sound insulation core
Flues1
Height25 m
Ø support pipe1016 mm
Ø inner pipe804 mm
CountryGermany
System typeCHP
SeriesFS-RM
ProductFS-RM
Product satellites5x DW-KL 
Flues5
Height19,7 m
Ø support pipe600 mm
Ø satelliteseach 130 mm
CountrySweden
System typeGenerators / emergency power generators
SeriesLattice mast chimney
Product14x Lattice mast chimney inkl. element chimneys, 28x connecting pipes
Flues28
Height mast14 m 
Ø exhaust pipeeach 600 mm
Length of exhaust pipeseach 10,6 m
CountryGermany
System typeMelting furnace
Series FSA
ProductFSA
Flues1
Height45 m 
Ø support pipe1450 mm
Ø inner pipe1204 mm 
CountryGermany
System typeBoiler
Series FSA-X, silencer
ProductFSA-2,
2 baffle silencers,
2 resonance silencers
Flues2
Height27,2 m
Ø support pipe2850 mm
Ø inner pipeeach 1254 mm

FSA-2 were connected to two double flame tube boilers (reserve boilers). Since both burners run in parallel, one exhaust flue was installed for each.

Firing capacity per boiler: 31,120 kW
Exhaust gas temperature according to Economister: 100°C
Dry volume flow: 30,344 Nm³/h

Specification: Maintain a sound conduction level of 91 dB
Solution: Custom-made: One primary silencer (resonance silencer) for each horizontal connecting line and one secondary silencer (absorption baffle set consisting of 2 baffles) for each of the vertically running inner pipes

Both inner pipes equipped with 6 measuring nozzles --> very complex. Access via a measuring platform with a running width of 1250 mm

CountryGermany
System typeGenerators / emergency power generators
SeriesFSA-X
Product2x FSA-4
Flues8
Height26,7 m
Ø support pipeeach 2200 mm
Ø inner pipeeach 604 mm
CountryGermany
System typeBoiler
Series FS-RM
ProductFS-RM 
Product SatellitesDW-AL
DW-SILVER
Flues2
Height10 m
Ø Mast0,5 m 
Ø Satelliteeach 300 mm
CountryGermany
System typeBoiler
Series FSA-RM
ProductFSA-RM
Flues1
Height17 m 
Ø support pipe813 mm
Ø inner pipe554 mm
CountryGermany
System typeBoiler
Series FSA, silencer
ProductFSA, combined silencer
Flues1
Height39,7 m
Ø support pipe1220 mm
Ø inner pipe904 mm

Combined silencer KSD with a noise reduction class of up to 35 dB.

CountryAustria
System typeBoiler
Series FSA
ProductFSA
Flues1
Height18 m
Ø support pipe660 mm
Ø inner pipe504 mm
CountryGermany
System typeBoiler
Series FSA-X, silencer
ProductFSA-5, Absorption silencer
Flues5
Height56,3 m
Ø Support pipe1500 mm
Ø Inner pipe504 mm, 2x 404 mm, 2x 104 mm

Special silencer AVD for biomass with a noise reduction class of up to 25 dB

Temperature up to 600°C

Max. pressure range 5000 Pa

CountryCzech Republic
System typeCHP
SeriesFSA
ProductFSA
Flues1
Height15,5 m
Ø support pipe1016 mm
Ø inner pipe804 mm
CountryGermany
System typeBoiler
Series FSA-X
ProductFSA-2
Flues2
Height32 m
Ø support pipe2175 mm
Ø inner pipeeach 904 mm
CountryUnited Arab Emirates
System typeBoiler
Series FSA-X
ProductFSA-3
Flues3
Height30 m
Ø support pipe1700 mm
Ø inner pipeeach 579 mm

Manufactured according to American standards

Delivery possible in only 3 parts

With obstacle warning lights, ladder, and platform

CountryItaly
System typeBoiler
Series FSA
ProductFSA
Flues1
Height49,5 m
Ø support pipe2100 mm
Ø inner pipe1800 mm
CountryGermany
System typeCHP
Series FSA, silencer
ProductFSA, silencer
Flues1
Height21,63 m
Ø support pipe711 mm
Ø inner pipe504 mm

 

CountryItaly
System typeCHP
Series FSA-X
ProductFSA-3 
Flues3
Height30 m
Ø support pipe3150 mm
Ø inner pipeeach 1204 mm

with 360° measuring and discharge platform, swiveling jib, and painted in pastel blue.

CountryGermany
System typeBoiler
Series FSA-X
ProductFSA-2
Flues2
Height26 m
Ø support pipe2650 mm
Ø inner pipeeach 804 mm

 

CountryGermany
System typeCHP
Series FSA
ProductFSA
Flues1
Height24,16 m
Ø support pipe660 mm
Ø inner pipe354 mm

 

CountryGermany
System typeCHP
Series FSA-X
Product2x FSA-2
Flues4
Heighteach 31,7 m
Ø support pipeeach 1950 mm
Ø inner pipeeach 804 mm

 

CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height9,5 m
Ø support pipe508 mm
Ø inner pipe254 mm

 

CountryGermany
System typeVentilation
Series FSA-X, silencer
ProductFSA-4, silencer
Flues4
Height23,7 m 
Ø support pipe2800 mm
Ø inner pipe2x 904 mm, 2x 1104 mm

 

CountrySwitzerland
System typeGenerators / emergency power generators
Series FSA
Product10x FSA
Flues10
Heighteach 23,3 m
Ø support pipeeach 813 mm
Ø inner pipeeachje 504 mm

First construction phase: The first 10 FSA for emergency power generators were installed here. A second order for another 5 FSA followed some time later.

CountryItaly
System typeCHP
Series FSA-X
ProductFSA-2
Flues2
Height30 m
Ø support pipe2950 mm
Ø inner pipeeach 1204 mm

with 360° measuring platform and swiveling jib.

CountryBelarus
System typeVentilation
Series FSA
Product6x FSA
Flues6
Height3x 15,7 m, 3x 12,89 m
Ø support pipe3x 2000 mm, 2x 914 mm, 711 mm
Ø inner pipe3x 1804 mm, 2x 704 mm, 504 mm

 

CountryGermany
System typeCHP
Series FSA-X, silencer
ProductFSA-5, silencer
Flues5
Height16 m
Ø support pipe1550 mm
Ø inner pipe5x 404 mm, 254 mm

3 combined silencers, 3 flue gas pipes, and one FSA with 5 inner pipes
3 CHP units with 1.5 MW serve the heat supply for the new greenhouse halls of the company "Gemüse Scherzer"

CountryGermany
System typeRoasting machine
Series FSA-X
ProductFSA-4
Flues4
Heighteach 17,6 m 
Ø support pipe1420 mm
Ø inner pipe2x 204 mm, 454 mm and 564 mm

Two inner pipes are used for dust extraction (temperature 50°C), inner pipe 3 is used for exhaust gas from the roasting process (temperature approximately 750°C), and the 4th inner pipe is used for exhaust gas from the cooling process.

CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height10 m
Ø support pipe711 mm
Ø inner pipe504 mm

 

CountryItaly
System typeBiomass
Series FSA
ProductFSA
Flues1
Height25 m
Ø support pipe1016 mm
Ø inner pipe854 mm

 

CountrySlovenia
System typeGas turbine
Series FSA, silencer
Product2 FSA, silencer
Flues2
Height11  m (A), 22,5 m (B)
Ø support pipe2500 mm (A), 1700 mm (B)
Ø inner pipe2204 mm (A), 1504 mm (B)

FSA "A" with 6 sound insulation panels and connection pipe
FSA "B" with vibration silencer and measuring platform

CountryItaly
System typeBoiler
Series Lattice mast chimney, silencer
ProductLattice mast chimney, DW-KL, silencer
Flues2
Length80 m
Height mast20 m
Ø exhaust pipeeach 700 mm
CountryGermany
System typeBoiler
Series FSA-X, silencer
ProductFSA-2, silencer
Flues2
Height31 m
Ø support pipe1900 mm
Ø inner pipeeach 804 mm

 

CountryGermany
System typeVentilation
Series FSC
Product3x FSC
Flues3
Height14,48 m
Ø support pipe2x 754 mm, 504 mm
Ø inner pipe2x 710 mm, 400 mm

 

CountryGermany
System typeCHP, Boiler
Series FSA-X
ProductFSA-6
Flues6
Height38,5 m
Ø support pipe1700 mm
Ø inner pipe2x 405 mm, 4 x 304 mm

In this project, the two inner pipes with a diameter of 405 mm were each connected to a Jenbacher CHP unit with 999 kW. The overall efficiency of 92.3% and thermal output of 716 kW speak for themselves.

An additional four inner pipes (diameter 304 mm) are planned for the future connection of four steam boilers and could be connected at any time.

CountryGermany
System typeCHP, Boiler
Series FSA-X-RM
ProductFSA-2-RM
Product satellitesDW-AL
Flues4
Height19 m
Ø support pipe1016 mm
Ø inner pipe154 mm, 254 mm
Ø Satelliteeach 350 mm 

 

CountryGermany
System typeBoiler
Series FSA-X, silencer
ProductFSA-2, silencer
Flues2
Height21 m
Ø support pipe2650 mm
Ø inner pipeeach 1154 mm
CountryGermany
System typeVentilation
Series FSA
ProductFSA
Flues1
Height36,7 m
Ø support pipe2900 mm
Ø inner pipe2706 mm

 

CountryGermany
System typeVentilation
Series FSC
ProductFSC
Flues1
Height35,3 m 
Ø support pipe2800 / 2520 mm

 

CountryGermany
System typeBoiler
Series FSA
ProductFSA
Flues1
Height19,5 m
Ø support pipe1050 mm
Ø inner pipe800 mm

 

CountryPoland
System typeBoiler
Series FSA
Product3x FSA
Flues3
Heighteach 19,7 m
Ø support pipe914 mm, 1016 mm, 711 mm
Ø inner pipe654 mm, 804 mm, 504 mm

 

CountryGermany
System typeBoiler
Series FSA
Product2x FSA
Flues2
Heighteach 14,7 m
Ø support pipeeach 813 mm
Ø inner pipeeach 604 mm

 

CountryGermany
System typeGenerators / emergency power generators
SeriesFSB
Product18x FSB
Flues18
Heighteach 31,35 m
Ø support pipeeach 813 mm
Ø inner pipeeach 604 mm

All 18 FSBs were fitted with a high-gloss stainless steel cladding. In addition, the chimneys are all identical and delivered in two sections (15 m each) and equipped with a muzzle and deflector hood.

CountryItaly
System typeBoiler
Series Lattice mast chimney, silencer
ProductLattice mast chimney, DW-ECO 2.0, silencer
Flues2
Height mast30 m
Ø Satellite450 mm