Lightweight Chimney System for Oil and Gas Heating Appliances

The lightweight shaft system FURADO-A, consisting of calcium silicate fire protection panels, Jeremias inner pipes from the EW-KL, EW-AL-BI, EW-PPS, or EW-PP-FLEX systems, and 25 mm thick insulation shells depending on the exhaust temperature, is used in connection with heating appliances powered by oil or gas. The roof installation can be carried out using either a shaft and cladding or stainless steel pipes.
 

Alternatively, the FURADO-A can also be used as an installation shaft for receiving CE-certified inner pipes and, depending on the exhaust temperature, with 25 mm insulation shells.
 

SYSTEM_DETAIL_ICONS


Product Description

Features

  • Excellent insulation properties
  • Easy to handle and install due to the low weight
  • Secure connection technology through tongue-and-groove joints
  • Various inner pipe solutions and shaft claddings meet all requirements
  • Low distances to combustible materials
  • 25 m shaft installation height without intermediate supports
  • Structural set for roof heights up to 3 m

Applications

  • Standard appliances for oil, gas
  • New construction and renovation
  • Condensing boilers
  • Combined Heat and Power (CHP) units, combustion engines
  • Gas-powered heat pumps
  • Fuel cells

 

Technical Data

MaterialCalcium silicate fire protection plates
Wall thickness60 mm
Others on request
Internal shaft dimension140 x 140 mm to 330 x 330 mm
Others on request
Insulationup to 160°C exhaust temperature, no insulation required
above 160°C exhaust temperature, minimum 25 mm insulation shells required
Annular gapup to 160°C, minimum 20 mm gap between inner pipe and chamber interior
above 160°C, minimum 20 mm gap between insulation and chamber interior
SealingEPDM-Sealing ALBI367 (up to120°C)
Silicone-Sealing ALBI26 (up to 200°C)
FURADO-A

APPROVAL NUMBER

nstallation Shaft Approvals:
Z-7.4-3478 / Z-7.4-3482 / Z-7.4-3483

CLASSIFICATIONS ACCORDING TO DIN V 18160-1

For Oil and Gas Appliances:
Installation Shaft Approvals:

T160 - LA90 oder T160 - LA30
(Wall thickness of shaft 60mm (LA90) or 50mm (LA30),
minimum 20mm annular gap, no distance to combustible materials)

T200 - LA90
(Wall thickness of shaft 50mm (LA90), 25mm insulation,
minimum 20mm annular gap, no distance to combustible materials)

T400 - LA90
(Wall thickness of shaft 50mm (LA90), 25mm insulation,
minimum 20mm annular gap,
minimum 50mm distance to combustible materials)

T600 - LA90
(Wall thickness of shaft 60mm (LA90), 25mm insulation,
minimum 20mm annular gap,
minimum 50mm distance to combustible materials)


Info:
EPDM-Sealing ALBI367 (up to120°C)
Silicone-Sealing ALBI26 (up to 200°C)

 

FURADO-A

CE CERTIFICATE NUMBER

0036 CPR 9174 074

0036 CPR 9174 075

CE CLASSIFICATIONS ACCORDING TO DIN EN 1856-1

EW-PP-FLEX DN60-110
T120 - H1 - W2 - O00 - LI - E - U0

EW-PP-FLEX > DN110-160
T120 - P1 - W2 - O00 - LI - E - U0

EW-PPS < DN200
T120 - H1 - W2 - O20 - LI - E - U

EW-PPS ≥ DN200
T120 - P1 - W2 - O20 - LI - E - U

CE CLASSIFICATIONS ACCORDING TO DIN EN 1856-1

For Oil and Gas Appliances:
T120 - P1 - W - V2 - L50050 - O00
(Wall thickness of shaft 60mm (LA90) or 50mm (LA30), minimum 20mm annular gap)
T160 - N1 - W - V2 - L50050 - O00
(Wall thickness of shaft 60mm (LA90) or 50mm (LA30), minimum 20mm annular gap)
T160 - P1 - W - V2 - L50050 - O00
(Wall thickness of shaft 60mm (LA90) or 50mm (LA30), minimum 20mm annular gap)
T160 - H1 - W - V2 - L50050 - O00
(Wall thickness of shaft 60mm (LA90) or 50mm (LA30), minimum 20mm annular gap)
T200 - N1 - W - V2 - L50050 - O00
(Wall thickness of shaft 50mm (LA90) or 25 mm, minimum 20mm annular gap)
T200 - P1 - W - V2 - L50050 - O00
(Wall thickness of shaft 50mm (LA90) or 25 mm, minimum 20mm annular gap)
T200 - H1 - W - V2 - L50050 - O00
(Wall thickness of shaft 50mm (LA90) or 25 mm, minimum 20mm annular gap)
T400 - N1 - W -  V2 - L50050 - Oxx
(Wall thickness of shaft 50mm (LA90) or 25 mm, minimum 20mm annular gap)
T400 - H1 - W - V2 - L50050 - Oxx
(Wall thickness of shaft 50mm (LA90) or 25 mm, minimum 20mm annular gap)
T600 - N1 - W - V2 - L50050 - Oxx
(Wall thickness of shaft 60mm (LA90) or 25 mm, minimum 20mm annular gap)
T600 - H1 - W - V2 - L50050 - Oxx
(Wall thickness of shaft 60mm (LA90) or 25 mm, minimum 20mm annular gap)

xx xx = The distances to combustible materials are
diameter-dependent, see performance declaration

 

Contact

How can we assist you?

Personalized advice, optimal service, and maintaining a close connection with our customers and partners are very important to us.
 

Do you have questions about our products, would you like a quote, or need assistance with planning your chimney project?

Feel free to get in touch, we would be happy to assist you!

Your Inquiry

You can find out about the processing of your personal data in the privacy policy.

Alternatively, you can also contact us by phone or email:

 

Customer Service

Anke Müller-Rohrbacher
Martina Losert
Cornelia Dietzsch

Phone: +49 9832 68 68 - 50
Fax: +49 9832 68 68 - 68
info@jeremias.de

Note for private individuals:
Since Jeremias does not sell directly to end customers,
no consultations are offered.
Please contact one of our chimney partners near you.

Sales Management for Modular Chimney Systems

Alexander Wening

Phone: +49 9832 68 68 - 50
Fax: +49 9832 68 68 - 68
vertriebsleitung@jeremias.de

 

Sales Management for Industrial Flue Gas Systems

Peter Veit

Phone: +49 9832 68 68 - 50
Fax: +49 9832 68 68 - 8686
peter.veit@jeremias.de