Systemicon Abgassysteme einwandig
Oil
Gas
Solid fuels
Over pressure up to 5000Pa
Wet operation mode
Temperature up to 600°C
Wall thickness 1.0mm
Discount group EW
25 years warranty

EW-KITCHEN KL

Single-wall, stainless steel chimney without seals for all kinds of commercial kitchen exhaust including charcoal grills, pizza ovensetc.

The EW-KITCHEN-KL system is our single-walled solution for commercial kitchen exhaust.
Our EW-KL system is extremely versatile thanks to a metallic-conical connection. The special form EW-KITCHEN KL was specially developed for use in commercial kitchens.
The combination of pressure tightness of up to 5000 Pa and high exhaust gas temperatures of up to 600°C means that conventional seals are no longer required.

It is suitable for various cooking appliances such as charcoal grills and pizza ovens and offers a high level of safety and reliability in the field of.

 

SYSTEM_DETAIL_ICONS


Product Description

Features

  • Metal conical connection
  • Pressure tight up to 5000 Pa without flanges and separate gasket
  • KLK straight pipe elements that can be conically shortened are available
  • Quick, easy installation
  • Resistant to soot fires and moisture

Applications

  • Commercial kitchen exhaust
  • Charcoal grills
  • Pizza ovens

Technical Data

Material1.4301 (304) 
Wall Thickness1,0 mm mat
Inner Diameter80 - 600 mm
Others on request up to 1000mm
ConnectionConical connection technology
Socket / bead and clamping band (optional)
EW-KITCHEN KL

CE CERTIFICATE NUMBER

0036 CPR 9174 004

CE CLASSIFICATIONS ACCORDING TO DIN EN 1856 - 1

T200 - P1 - W - V2 - L50060 - O00
T200 - H1 - W - V2 - L50060 - Oxx
T400 - N1 - D - V2 - L50060 - Gxx
T400 - P1 - W - V2 - L50060 - Oxx
T450 - H1 - W - V2 - L50060 - Oxx
T600 - N1 - D - V3 - L50060 - Gxx 1
T600 - P1 - W - V2 - L50060 - Oxx
T600 - H1 - W - V2 - L50060 - Gxx

1 with 25 mm insulation
xx = Distances to combustible materials are diameter-dependent, see performance declaration

 

EW-KITCHEN KL CONNECTION PIPE

CE CERTIFICATE NUMBER

0036 CPR 9174 042

CE CLASSIFICATIONS ACCORDING TO DIN EN 1856-2

T200 - P1 - W - V2 - L50060 - O50M
T200 - H1 - W - V2 - L50060 - O50M
T400 - H1 - W - V2 - L50060 - G500M
T400 - N1 - D - V2 - L50060 - G400M
T400 - N1 - D - V2 - L50060 - G3001

1 with radiation protection

Contact

How can we assist you?

Personalized advice, optimal service, and maintaining a close connection with our customers and partners are very important to us.
 

Do you have questions about our products, would you like a quote, or need assistance with planning your chimney project?

Feel free to get in touch, we would be happy to assist you!

Your Inquiry

You can find out about the processing of your personal data in the privacy policy.

Alternatively, you can also contact us by phone or email:

 

Customer Service

Anke Müller-Rohrbacher
Martina Losert
Cornelia Dietzsch

Phone: +49 9832 68 68 - 50
Fax: +49 9832 68 68 - 68
info@jeremias.de

Note for private individuals:
Since Jeremias does not sell directly to end customers,
no consultations are offered.
Please contact one of our chimney partners near you.

Sales Management for Modular Chimney Systems

Alexander Wening

Phone: +49 9832 68 68 - 50
Fax: +49 9832 68 68 - 68
vertriebsleitung@jeremias.de

 

Sales Management for Industrial Flue Gas Systems

Peter Veit

Phone: +49 9832 68 68 - 50
Fax: +49 9832 68 68 - 8686
peter.veit@jeremias.de